TENSÍÍO

The new generation tensiometer for liquid and solid surfaces

Theoretically, building a tensiometer is simple: putting a moveable sample stage underneath a force measuring device. But developing the best-in-class tensiometer is something completely different. It takes more than just using an utterly precise force sensor (which we did) and the most sample positioning with the widest dynamic range (which we developed). It takes a change of perspective that focuses on the user and his task – you and your task. It takes the will to make your lab work as convenient, flexible, and time-saving as possible. We believe that Tensíío is that kind of instrument.

Additional information
INSTRUMENT DIMENSIONS

Footprint: 290 mm × 360 mm (W × D)
Height: 560 mm
Weight: (without accessories) 29 kg

TEMPERATURE MEASUREMENT

Resolution: 0.01 °C
Precision: 0.05 °C
Accuracy: 0.5 °C
Internal sensor: sample stage
External sensor: optional: sample vessel

ENVIRONMENT

Operating temperature: 15 to 30 °C
Humidity: > 30% without condensation

TEMPERATURE CONTROL

Type of temperature control: liquid (-10 to 130 °C)
electrical: (50 to 300 °C)
Peltier: (-15 to 135 °C)
Range of temperature control: -15 to 300 °C

CAMERA SYSTEM (STANDARD)

Connection USB 3.0
Performance 15 fps at 2560 × 1920 px

OPTICS (STANDARD)

Focus: fixed
Zoom: 1.4× zoom, fixed
Field of view: 6 mm × 4.5 mm
Resolution of optics: 2.3 µm

FORCE MEASUREMENT

Maximum load: 210 g
Resolution: 10 µg
Measurement rate: 50 Hz
Adjustment: fully automated
internal weigth
Locking mechanism: automatic

SURFACE FREE ENERGY OF SOLIDS

Zisman
Fowkes
Wu
Owens-Wendt-Rabel-Kaelble
extended Fowkes
acid-base theory

WASHBURN

Results: contact angle (CA)
Resolution: 0.01°
Range: 0 to 90°
Type: advancing

WILHELMY CONTACT ANGLE

Minimum fiber diameter: 20 µm
Results: contact angle (CA)
Range: 0 to 180°
Resolution: 0.01°
Type: advancing
receding

WILHELMY PLATE

Results: surface tension (SFT)
interfacial tension (IFT)
critical micelle concentration (CMC)
Range: 1 to 2000 mN/m
Resolution: 0.002 mN/m

DU NOÜY RING

Results: surface tension (SFT)
interfacial tension (IFT)
critical micelle concentration (CMC)
Range: 1 to 2000 mN/m
Resolution: 0.001 mN/m
Correction method: Harkins-Jordan
Huh-Mason
Zuidema-Waters
linear correction
no correction

LIQUID DENSITY

Liquid density range: 1 to 2200 kg/m³
Resolution: 0.1 kg/m³
Precision: 3 kg/m³

SOLID DENSITY

Solid density range: 1000 to 20000 kg/m³
Resolution: 1 kg/m³
Precision: ±3 kg/m³

ROD

Results: surface tension (SFT)
interfacial tension (IFT)
critical micelle concentration (CMC)
Range: 1 to 2000 mN/m
Resolution: 0.02 mN/m

PENETRATION

Results: graph – mass vs. time

SEDIMENTATION

Results: graph – mass vs. time

Download PDF